Product Testing > Notes and Reviews > Flammability Testing > T17H: Surface Burning
AWTA TEST CODE
:
T17H
OTHER NAMES
TEST METHODS
AS 2755.3 AS 1249 ISO 10047 ASNZS 1754
IMAGE
Sample Undergoing Surface Burn Test
APPLICATION
This method is applicable to textile fabrics which have a raised fibre surface, ie napped, pile, tufted, flocked or similar surface.
PRINCIPLE
A dry specimen of the fabric being tested is supported on a vertical plate and its raised or napped surface is ignited near the top in a standard manner. The spread of flame downwards on the surface of the fabric to a reference line is timed.
SAMPLES REQUIRED FOR TESTING
Sufficient to cut 8 specimens, each 150mm x 75mm.
INTERPRETATION
AS 1249 - Children's Nightclothes Having Reduced Fire Hazard, requires that fabrics with a nap or pile shall have a surface burning time of 10 seconds or greater after being subjected to a standard washing procedure.
SERVICE TARGET
4 days.
COST
See current Fees List.